Strona 1 - Heat Stress Trackers

AVAILABLE WITHWIRELESS DATA TRANSFERHeat Stress TrackersNKhome.com800.784.4221KESTREL 4400 & 4600INSTRUCTIONAL MANUAL

Strona 2

1918Replacing the Kestrel impeller Press only the sides of the impeller when removing and inserting to avoid damaging the precision hub bearing. (

Strona 3 - Figure 1

2120Measuring Direction The Kestrel 4600's digital compass must be vertical to achieve accurate readings. Keep the unit positioned as close to

Strona 4

232258.5WET BULB FGlobe Temperature The Black Globe on the Kestrel Heat Stress Trackers is representative of the amount of heat-absorption via the col

Strona 5 -  1014.6 inHg

A24Maintenance & StorageTo avoid scratching the window, store the Kestrel Heat Stress Tracker in the soft pouch and/or use the Kestrel lens cleani

Strona 6 - WBGT in F

2726NOTES: 5YEAR LIMITED PRODUCT WARRANTYYour Kestrel Heat Stress Tracker is warrantied to be free of defects in materials and workmanship for a per

Strona 7 - RESTRAINTS ON ACTIVITIES

28This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful inte

Strona 8 - Buer Withdrawal

32To maximize the accuracy and reliability of your readings:• Ensure that your Kestrel Meter is in good repair and within factory calibration.• Take

Strona 9

54FRONTBACKDATA UPLOAD OPTICAL COUPLERSERIAL NUMBERAAA BATTERIES (2)AMBIENT TEMPERATURE SENSOR PRESSURE SENSORCAUTION - DO NOT POKE!STABILIZING BATTER

Strona 10 - 4600 ONLY

76Battery Installation• Insert batteries into bottom of Kestrel unit as shown on battery door. • Snap door closed.KESTREL 4600:AAA batteries have a

Strona 11

98MeasurementsUse this setup to “hide” unwanted Measurement screens from the normal Measurement navigation.• Use or to scroll to the desired Meas

Strona 12 - T = Dry Bulb Temperature

1110Measuring The unit will calculate and display Wet Bulb Globe Temperature based on Globe Temperature, Relative Humidity, Ambient Temperature, Baro

Strona 13

1312Figure 4: Work/Rest ratios and Water Consumption Guidelines. (Source: U.S. Army Center for Health Promotion and Preventive Medicine Health Inform

Strona 14 - 5-YEAR LIMITED WARRANTY

1514THERMAL WORK LIMIT TWL 4400 ONLYMeasuring The unit will also display a measure of human heat stress known as “Thermal Work Limit,” or “TWL.”

Strona 15 - NK#xxxx_1_13.3.19

1716BLUETOOTH® SETUPBLUETOOTH SETUP (BLUETOOTH ENABLED METERS ONLY)To transfer your Kestrel’s real-time and logged data wirelessly and automatically